LP Gas Outdoor Fireplace Model No. GAD1321SP Series
Installing LP Gas Tank
To operate, you will need (1) precision-filled standard grill LP gas
tank (20#) with external valve threads.
W CAUTION: LP gas tank must be properly
disconnected and removed prior to moving this
outdoor fireplace.
Insert and Secure LP Gas Tank
W WARNING: Make sure LP gas tank valve is closed. Close by turning
valve clockwise.
1. Loosen LP gas tank retainer bolt by turning counter-clockwise.
2. Place precision filled LP gas tank upright into hole in the base of the outdoor fireplace so it
is arranged for vapor withdrawal.
3. Secure tank by turning LP gas tank retainer bolt clockwise.
Connect LP Gas Tank
Before connecting, be sure that there is no debris caught in the
head of the LP gas tank, head of the regulator valve or in the
head of the burner and burner ports.
Connect regulator/hose assembly to tank by turning knob
clockwise until it stops.
Disconnect LP Gas Tank
Before disconnecting make sure the LP gas tank valve is
“CLOSED.”
Disconnect regulator/hose assembly from LP gas tank by turning
knob counterclockwise until it is loose.
W CAUTION: LP gas tank must be properly
disconnected and removed prior to moving
this outdoor fireplace.
Getting More Propane
Need a tank of gas? One option is to try propane exchange. It’s easy, fast,
safe, and available at tens of thousands of conveniently located retail outlets
nationwide, which are typically open on nights and weekends. You can
purchase a fresh, precision-filled tank or exchange your empty for a fresh,
precision-filled tank. Another option is to have your tank refilled at a refill
station. Be sure to check the hours of operation for the refill station.
20 lb
9 Kg
17.9 in. / 45.5 cm
12.2 in. / 31 cm
Checking for Leaks
W WARNING: Before using this outdoor
fireplace, make sure you have read,
understand and are following all
information provided in the Dangers
and Warnings presented on page 2.
Failure to follow those instructions
can cause death, serious injury or
property damage.
Burner Connections
1. Make sure the regulator valve and hose
connections are securely fastened to the burner
and the tank. If your unit was assembled for
you, visually check the connection between the
burner venturi pipe and orifice. Make sure the
burner venturi pipe fits over the orifice.
W WARNING: Failure to inspect
this connection or follow these
instructions could cause a fire or an
explosion which can cause death,
serious bodily injury, or damage to
property.
2. Please refer to diagram for proper installation.
(Figure 1)
3. If the burner pipe does not rest flush to the
orifice, please contact 1.800.762.1142 for
assistance.
Tank/Gas Line Connection
1. Make 2-3 oz. of leak solution by mixing one part
liquid dishwashing soap with three parts water.
2. Make sure control knobs are in the “OFF
position. (Figure 3)
3. Connect LP gas tank per “Installing LP Gas
Tank” section.
4. Turn LP gas tank valve to “OPEN.”
5. Spoon several drops of solution, or use squirt
bottle, at all “X” locations (Figures 1 and 2).
a. If any bubbles appear remove the LP gas tank
and reconnect, making sure the connection
is secure.
b. If you continue to see bubbles after several
attempts, remove the LP gas tank per
“Disconnect LP Gas Tank” instructions, and
contact 1.800.762.1142 for assistance.
c. If no bubbles appear after one minute, wipe
away solution and proceed.
Lighting
W Caution: Keep outdoor gas appliance
area clear and free from combustible
materials, gasoline and other
flammable vapors and liquids.
W Caution: Do not obstruct the flow of
combustion and ventilation air.
W Caution: Check and clean burner/
venturi tubes for insects and insect
nests. A clogged tube can lead to a
fire beneath the outdoor fireplace.
W Caution: Attempting to light the burner with the lid closed may cause
an explosion.
1. Make sure all labels, packaging and protective films have been removed from the outdoor
fireplace.
2. Make sure there are no obstructions of airflow to the burners. Spiders and insects can nest
within and clog the burner / venturi tube at the orifice. A clogged burner tube can lead to a
fire beneath the appliance.
3. Control knob must be in the
(OFF) position. (Figure 3)
4. Clear small area of glass rocks or lava rocks away from the pilot housing.
5. Connect LP gas tank per “Connect LP Gas Tank” instructions.
6. Turn LP gas tank valve to “OPEN.”
7. Push and turn control knob to
(LOW).
8. Press the
(electronic igniter) button and hold for up to 5 seconds to light the pilot.
9. Hold the control knob in for 20 seconds to heat thermocouple.
10. After 20 seconds, release and turn control knob counter-clockwise to igniter burner and
adjust flame to desired height.
11. If ignition does not occur in 5 seconds, turn control knob
(OFF), wait 5 minutes, and
repeat lighting procedure.
Figure 1
XX
X
X
X
X
LP Gas Valve
with Orifice
LP Gas
Connection
Figure 2
X
X
X
X
X
Figure 3